AIPS is commited to provide you the ultimate prevention at the highest level. We provide a professional approach to protection.Therefore, we offer you the best Fire Detection System in India. Fire detection systems are meant to determine fires early in their growth when there is still enough time for inhabitants to evacuate safely. Early detection is also crucial for ensuring the safety of emergency responders.
Early detection can limit property loss and reduce downtime for the operation since control operations can begin while the fire is still small. Most alarm systems give emergency responders information on the location of the fire, which speeds up the firefighting operation.
Alarm systems usually send a signal to a staffed monitoring station, either on-site or off-site, and offer a warning to at least the building's residents. Alarms may be sent straight to the fire department in some situations. However, this is no longer the standard procedure in most places. Detectors must be used in conjunction with alarms to be effective.
As previously said, these systems have various advantages. The fact that they do nothing to contain or control the fire is a considerable drawback. Fire suppression systems, such as automated sprinklers, are used to keep the fire under control. They also provide notification that they are working. Therefore if connected to notification appliances throughout the building, they can serve as a heat detection-based system. However, they will not react as quickly as a smoke detection system. This is why, even if sprinklers are installed, facilities that require immediate notification require fire detection and alarm systems.
The detection devices, ranging from sophisticated, intelligent smoke detectors to uncomplicated manually operated break glass units, are at the heart of a fire alarm system. There are many different types, but we can divide them into groups such as:
Heat Detectors
Heat detectors can work on a specified temperature basis, triggering an alarm if the temperature exceeds a pre-set threshold, or they can work on the rate of temperature change.
Heat detectors function similarly to an electrical fuse in that they contain a heat-sensitive eutectic alloy that converts from a solid to a liquid when a specified temperature is attained, triggering the alarm.
Smoke Detectors
Smoke detectors are divided into three categories:
Ionization Smoke Detector
Ionization A typical smoke detector has two chambers. The first is employed as a baseline against which ambient temperature, humidity, or pressure changes are compensated.
A radioactive source, usually an alpha particle, is used in the second chamber to ionize the air flowing through the chamber, where a current travels between two electrodes.
The current flow diminishes when smoke enters the chamber. An alert is triggered when the current flow drops.
Smoke Detector with Light Scattering
The Tyndall effect is used in the light scattering smoke detector; a photocell and light source are separated by a darkened chamber so that the light source does not fall on the photocell.
The light from the source is scattered and falls on the photocell due to the smoke entering the chamber. An alert is triggered using the photocell output.
Smoke Detector With Light Obstruction
Smoke obstructs a light beam between a light source and a photocell in the light, obscuring the smoke detector. The photocell determines how much light it receives.
The variation in photocell output triggers the alert with the light source and photocell spaced apart. This sort of fire detection system can be utilized to safeguard broad regions
Carbon Monoxide Detectors
Carbon monoxide detectors, often known as CO fire detectors, are electronic detectors that detect the presence of carbon monoxide in the air to signal the start of a fire.
Carbon monoxide is a toxic gas that is created when fuel is burned. These detectors are not the same as carbon monoxide detectors used in homes to protect inhabitants against carbon monoxide created by incomplete combustion in appliances like gas fireplaces or boilers.
Carbon monoxide fire detectors have the same type of sensor as home smoke detectors, but they are more sensitive and respond faster. An electrochemical cell in carbon monoxide detectors detects carbon monoxide but not smoke or other combustion products.
Detectors With Many Sensors
Multi-sensor detectors combine optical and thermal sensor inputs and process them using a complex algorithm incorporated into the detector electronics.
The detector returns a value based on the combined responses from the optical and heat sensors when polled by the control panel. They're made to be sensitive to a variety of flames.
Manual Call Points
A Manual Call Point, also known as a Break Glass Call Point, is a mechanism that authorizes staff to activate the alarm by breaking the frangible element on the fascia.
There are four different types of fire alarm systems:
Standard Fire Alarm Systems
When these devices are triggered, they sound the alarm.
Fire Alarm Systems With Addressability
The detection concept of an Addressable System is similar to that of a Conventional System, except that each detector is assigned a unique address (typically via a dip-switch), allowing the Control Panel to pinpoint which detector or call point has triggered the alert.
The detection circuit is wired as a spiral, with each loop capable of connecting up to 99 devices. Loop Isolation Modules are commonly used to section the loop such that a short circuit or single fault only affects a small portion of the system, leaving the remainder of the system to function normally.
The detectors in the preceding two systems, the "Conventional Fire Alarm System" and the "Addressable Fire Alarm System," are not deemed "intelligent" because they can only produce output signals that represent the value of detected phenomena.
The Control Unit is in charge of determining whether there is a fire, malfunction, pre-alarm, or other emergencies.
Fire Alarm Systems That Are Intelligent
In our next system, an Intelligent Fire Alarm System, each detector effectively includes its computer, which analyses its environment and transmits to the Control Panel whether there is a fire, a problem, or the detector head needs cleaning.
Intelligent Systems are, in essence, significantly more complicated and include many more features than conventional or addressable systems. Their main goal is to assist avoid false alarms from occurring.
Intelligent fire alarming systems come in 2, 4, and 8 loop configurations, allowing significant buildings to be monitored from a single panel.
System for Wireless Fire Alarms
The Wireless fire alarm system is the last type of system we'll look at.
These are a viable alternative to standard wired fire alarming systems for all applications. To connect the sensors and equipment to the controllers, they use secure, license-free radio communications.
It's a basic concept with many benefits, and it's a comprehensive intelligent fire detection system in India that doesn't require any wiring. We learned in this article that fire alarm systems are installed in many of the buildings we see on a daily basis and that they are used to warn individuals inside the establishment of an emergency fire situation.
Early discovery of a fire, while it is still small, is critical for your people's safe escape. With fire detection and alarm systems, you can protect your most valuable assets – both people and property – from the start from the terrible repercussions of a fire.
Flame And Smoke Detection System
The purpose of a flame detector is to detect the presence of fire. They detect radiation emitted by a flame using UV and infrared sensors and can be directly linked to an alarm system or an automatic fire extinguishing system. Specialized flame detectors are also employed in natural gas turbines to check the presence of a pilot flame, greatly boosting gas turbine performance while lowering maintenance costs.
AIPS Fire detection systems are meant to determine fires early in their growth when there is still enough time for inhabitants to evacuate safely. Early detection is also crucial for ensuring the safety of emergency responders.
Early detection can limit property loss and reduce downtime for the operation since control operations can begin while the fire is still small. Most alarm systems give emergency responders information on the location of the fire, which speeds up the firefighting operation.
Our Alarm systems send a signal to a staffed monitoring station, either on-site or off-site, and offer a warning to at least the building's residents. Alarms may be sent straight to the fire department in some situations.Our Detectors must also be used in conjunction with alarms to be effective.
As previously said, these systems have various advantages. The fact that they do nothing to contain or control the fire is a considerable drawback. Our Fire suppression systems, such as automated sprinklers, are used to keep the fire under control. They also provide notification that they are working. Therefore if connected to notification appliances throughout the building, they can serve as a heat detection-based system. However, they will not react as quickly as a smoke detection system. This is why, even if sprinklers are installed, facilities that require immediate notification require fire detection and alarm systems.